1-5
Instruction Manual
IM-106-880, Rev 2.1
April 2017
OCX 8800
The power supply can accept voltages of 100 to 240 VAC and 50 to 60 Hz.
The electronics accepts millivolt signals generated by the sensors and
produces the outputs to be used by remotely connected devices. Refer to
Section 3, Configuration and Startup for specific instructions upon initial
power up.
System Features
1. The O
2
cell output voltage and sensitivity increase as the oxygen
concentration decreases.
2. HART or FOUNDATION fieldbus communication is standard. To use this
capability, you must have either:
a. Model 375 Field Communicator.
b. AMS software for the PC.
3. Oxygen cell and heater/thermocouple assembly are field replaceable.
4. Electronics are automatically configured for line voltages from 100 to
240 VAC.
5. An operator can calibrate and diagnostically troubleshoot the OCX 8800
in one of two ways:
a. LOI. The LOI is mounted to the end of the electronics module and
allows local communications with the electronics. Refer to Section 4,
Using the LOI, for more information.
b. HART or FOUNDATION fieldbus interface. The OCX 8800's output
line transmits a digital signal with the detected oxygen or
combustible levels encoded in a digital format. This information can
be accessed through the following:
• Model 375 Field Communicator - The handheld field
communicator requires Device Description (DD) software specific
to the OCX 8800. The DD software will be supplied with many
Model 375 units, but can also be programmed into existing units
at most Emerson service offices. Refer to Section 6, Field
Communicator, for additional information.
• Personal Computer (PC) - The use of a personal computer
requires AMS software available from Emerson.
• Selected Distributed Control Systems - The use of distributed
control systems requires input/output (I/O) hardware and AMS
software which permit HART or FOUNDATION fieldbus
communications.
6. When the transmitter is configured without the LOI an operator must
calibrate and diagnostically troubleshoot the OCX 8800 using the HART
or FOUNDATION fieldbus Interface.
7. Optional Blowback System. The blowback system periodically blows
instrument air back through the sample line filter and out the sample
tube. This clears out particulate and keeps the sample line filter from
clogging.
Summary of Contents for OCX 8800
Page 2: ......
Page 4: ......
Page 10: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 ii ...
Page 72: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 4 8 ...
Page 88: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 5 16 ...
Page 100: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 6 12 ...
Page 164: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 7 64 ...
Page 176: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 8 12 ...
Page 213: ......
Page 223: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 10 11 ...
Page 225: ......
Page 262: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 C 2 ...