![ROBBE-Futaba FX-32 Instruction Manual Download Page 125](http://html.mh-extra.com/html/robbe-futaba/fx-32/fx-32_instruction-manual_1468774125.webp)
125
<Model Menu (Airplane/Glider Functions)>
● S e l e c t t h e f u n c t i o n
name and return to the
preceding screen by
touching the
RTN
button
or pushing the
Home/Exit
button.
<SensorTouch™>
AIL 3
(Chip Aileron)
AIL 4
(Chip Aileron)
AIL1
(Main Aileron)
AIL 2
(Main Aileron)
FLP 2
(Camber Flap)
FLP 1
(Camber Flap)
AIL to CAMB.FLP
[Corresponding model type]: Airplane/glider, 2 ai 2 flaps or
more
This mix operates the camber flaps (FLP1/2)
in the aileron mode. When the aileron stick
is manipulated, the ailerons and camber flaps
perform aileron operation simultaneously and
the operation characteristic of the roll axis is
improved.
● The aileron left/right mixing rate of each flap servo
can be fine-tuned.
● A mixing curve can be set.
● An ON/OFF switch can be set.
● Linking is possible: Link this mix to other mixes.
● Mixing curve setting
*For a description of the curve setting method, see the
description at the back of this manual.
● Adjustment of each flap
servo
● L e f t / r i g h t o v e r a l l
adjustment at Rate A
and Rate B
Setting method
● Move the cursor to the ACT/INH item and
touch the RTN button to switch to the data
input mode.
Turn the touch sensor to the left and touch
the RTN button. (ON is displayed.)
● When setting a switch, move the cursor to
the [--] item of the switch and touch the RTN
button to call the selection screen, and then
select the switch and set its ON direction.
(Always ON at "--" setting)
(For a description of the switch selection
method, see the description at the back of
this manual.)
● Move the cursor to the left or right item of
each flap servo and touch the RTN button to
switch to the data input mode.
Adjust the mixing rate with the touch sensor.
Touch the RTN button to end adjustment and
return to the cursol move mode.
*When the mixing direction is reversed by the linkage,
adjustments can be made by changing the mixing rate
polarity (+ or -).
● A mixing curve can be set.
(For a description of the mixing curve setting
method, see the description at the back of
this manual.)
● To set linking, move the cursor to the [LINK]
item and touch the RTN button to switch to
the data input mode.
Set it to ON and touch the RTN button.
(Currently selected condition name)
● Select [AIL to CAMB.FLP] at the model
menu and call the setup screen shown
below by touching the RTN button.
● Group/single mode
switching
(For more information, refer to
the description at the back of
this manual.)
*The display screen is an example. The actual
screen depends on the model type.
Scrolling
● Moving cursor
● Selecting mode
● Adjusting value
● To next page
Summary of Contents for FX-32
Page 1: ...Instruction Manual FX 32 No F8078 ...
Page 9: ...9 Introduction Notes ...