Rev. 6.00, 08/04, page 158 of 628
Bit 0—Program (P)
This bit is to set changing to or cancelling program mode (do not set SWE, ESU, PSU, EV, PV,
and E bits at the same time).
Bit 0
P
Description
0
Program mode is cancelled
(initial value)
1
When this bit is set to 1, while the SWE = 1 and PSU = 1, the flash memory
changes to program mode.
6.6.2
Flash Memory Control Register 2 (FLMCR2)
Bit
7
6
5
4
3
2
1
0
FLER
—
—
—
—
—
—
—
Initial value
0
0
0
0
0
0
0
0
Read/Write
R
—
—
—
—
—
—
—
FLMCR2 is a register that displays the state of flash memory programming/erasing. FLMCR2 is a
read-only register, and should not be written to.
Bit 7—Flash Memory Error (FLER)
This bit is set when the flash memory detects an error and goes to the error-protection state during
programming or erasing to the flash memory. See section 6.9.3, Error Protection, for details.
Bit 7
FLER
Description
0
The flash memory operates normally.
(initial value)
1
Indicates that an error has occurred during an operation on flash memory
(programming or erasing).
Bits 6 to 0—Reserved
These bits are always read as 0 and cannot be modified.