Rev. 6.00, 08/04, page 267 of 628
TCF Clear Timing
TCF can be cleared by a compare match with OCRF.
Timer Overflow Flag (OVF) Set Timing
OVF is set to 1 when TCF overflows from H'FFFF to H'0000.
Compare Match Flag Set Timing
The compare match flag (CMFH or CMFL) is set to 1 when the TCF and OCRF values match.
The compare match signal is generated in the last state during which the values match (when TCF
is updated from the matching value to a new value). When TCF matches OCRF, the compare
match signal is not generated until the next counter clock.
Timer F Operation Modes
Timer F operation modes are shown in table 9.9.
Table 9.9
Timer F Operation Modes
Operation Mode
Reset
Active
Sleep
Watch
Sub-
active
Sub-
sleep
Standby
Module
Standby
TCF
Reset
Functions Functions Functions/
Halted
*
Functions/
Halted
*
Functions/
Halted
*
Halted
Halted
OCRF
Reset
Functions Held
Held
Functions
Held
Held
Held
TCRF
Reset
Functions Held
Held
Functions
Held
Held
Held
TCSRF
Reset
Functions Held
Held
Functions
Held
Held
Held
Note:
*
When
φ
w
/4 is selected as the TCF internal clock in active mode or sleep mode, since the
system clock and internal clock are mutually asynchronous, synchronization is maintained
by a synchronization circuit. This results in a maximum count cycle error of 1/
φ
(s). When
the counter is operated in subactive mode, watch mode, or subsleep mode,
φ
w
/4 must be
selected as the internal clock. The counter will not operate if any other internal clock is
selected.
Summary of Contents for H8/38024 Series
Page 18: ...Rev 6 00 08 04 page xviii of xxx...
Page 30: ...Rev 6 00 08 04 page xxx of xxx...
Page 130: ...Rev 6 00 08 04 page 100 of 628...
Page 216: ...Rev 6 00 08 04 page 186 of 628...
Page 416: ...Rev 6 00 08 04 page 386 of 628...
Page 432: ...Rev 6 00 08 04 page 402 of 628...
Page 468: ...Rev 6 00 08 04 page 438 of 628...
Page 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...