Rev. 6.00, 08/04, page 183 of 628
6.10.7
Status Polling
1. The I/O7 status polling flag indicates the operating status in auto-program/auto-erase mode.
2. The I/O6 status polling flag indicates a normal or abnormal end in auto-program/auto-erase
mode.
Table 6.21
Status Polling Output Truth Table
I/O7
I/O6
I/O0 to 5
Status
0
0
0
During internal operation
1
0
0
Abnormal end
1
1
0
Normal end
0
1
0
—
6.10.8
Programmer Mode Transition Time
Commands cannot be accepted during the oscillation stabilization period or the programmer mode
setup period. After the programmer mode setup time, a transition is made to memory read mode.
Table 6.22
Stipulated Transition Times to Command Wait State
Item
Symbol
Min
Max
Unit
Notes
Oscillation stabilization time(crystal oscillator)
T
osc1
10
—
ms
Figure 6.20
Oscillation stabilization time(ceramic oscillator)
T
osc1
5
—
ms
Programmer mode setup time
T
bmv
10
—
ms
Vcc hold time
T
dwn
0
—
ms
t
osc1
t
bmv
t
dwn
Vcc
RES
Auto-program mode
Auto-erase mode
Figure 6.20 Oscillation Stabilization Time, Boot Program Transfer Time,
and Power-Down Sequence
Summary of Contents for H8/38024 Series
Page 18: ...Rev 6 00 08 04 page xviii of xxx...
Page 30: ...Rev 6 00 08 04 page xxx of xxx...
Page 130: ...Rev 6 00 08 04 page 100 of 628...
Page 216: ...Rev 6 00 08 04 page 186 of 628...
Page 416: ...Rev 6 00 08 04 page 386 of 628...
Page 432: ...Rev 6 00 08 04 page 402 of 628...
Page 468: ...Rev 6 00 08 04 page 438 of 628...
Page 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...