RADWIN
5000
HPMP
User
Manual
Release
3.5.70
C
‐
76
MIB
Traps
pdTooHighDueCbwLimitations
132
major
Indicates
that
link
cannot
be
established
because
link
range
is
too
large
for
channel
bandwidth.
hbsEncryptionAlarm
133
major
Indicates
an
encryption
key
mismatch.
Contains
a
single
parameter
which
is
its
description
including
the
HSU's
name
hbsEhServiceClosedToHsu
134
major
Indicates
an
encryption
key
mismatch.
Contains
a
single
parameter
which
is
its
description
including
the
HSU's
name
hbsUnsynchronizedHsuAlarm
135
warning
Indicates
a
registered
HSU
lost
synchronization.
hbsInactiveHbsAlarm
136
major
Indicates
HBS
is
InActive.
incompatibleHsu
137
critical
Indicates
that
the
HSU
is
not
compatible
to
HBS.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Incompatible
ODUs.
hsuUnsupportedBeacon
138
warning
Indicates
an
unsupported
beacon
has
arrived
at
HSU
lanPortDisconnectedAlarm
139
major
Indicates
the
LAN
port
status
changed
to
disconnected.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
LAN
port
status
changed
to
disconnected.
poePortDisconnectedAlarm
140
major
Indicates
the
POE
port
status
changed
to
disconnected.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
POE
port
status
changed
to
disconnected.
poePowerConsumptionAlarm
141
major
Indicates
the
POE
Power
Consumption
is
above
allowed
maximum.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
POE
consumption
above
allowed
maximum.
port
closed.
hobupFaultyStateAlarm
149
major
This
Alarm
will
indicate
that
the
Hot
Backup
module
is
in
faulty
state.
1
‐
Description:
Hot
Backup
fault
detected:
%s
unit.
%s
‐
Primary
Or
Secondary
Unit
gpsOverCurrentAlarm
150
major
Indicates
the
GPS
Antenna
current
consumption
is
above
allowed
maximum.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
GPS
Antenna
current
consumption
above
allowed
maximum.
GPS
closed.
gpsCommunicationFailiureAlarm
151
major
Indicates
the
GPS
data
isn't
received.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
GPS
Communication
failiure.
temperatureThresholdAlarm
152
major
Indicates
the
board
temperature
is
above
allowed
maximum.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
GPS
Antenna
current
consumption
above
allowed
maximum.
GPS
closed.
localRouterDiscoveryStatus
153
major
This
Alarm
will
indicate
that
we
have
no
connection
with
Track
side
router.
1
‐
Description:
MacLearningUpdate
detected
disconnection
with
Track
side
router
%s
%s
‐
Default
gateway
IP
TrackRouterDiscoveryStatus
154
major
This
Alarm
will
indicate
that
we
have
no
connection
with
Track
side
router.
1
‐
Description:
MacLearningUpdate
detected
disconnection
with
Track
side
router
%s
%s
‐
Default
gateway
IP
btsTargetUnreachable
156
major
This
Alarm
will
indicate
that
we
have
no
connection
with
Bts
desired
target.
1
‐
Description:
TNC
detected
disconnection
with
the
BTS
target
%s
%s
‐
Default
gateway
IP
Table
C
‐
4:
MIB
Traps
(Sheet
5
of
8)
Name
ID
Severity
Description
Summary of Contents for 5000 HPMP
Page 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Page 21: ...Part 1 Basic Installation Release 3 5 70...
Page 69: ...Part 2 Sector Installation Release 3 5 70...
Page 155: ...Part 3 Sector Management Release 3 5 70...
Page 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Page 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Page 290: ...Part 4 Site Synchronization Release 3 5 70...
Page 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Page 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Page 354: ...Part 6 Field Installation Topics Release 3 5 70...
Page 396: ...Part 7 Product Reference Release 3 5 70...
Page 517: ......