RADWIN
5000
HPMP
User
Manual
Release
3.5.70
C
‐
11
Private
MIB
Parameters
winlink1000OduAirRxPower
1.3.6.1.4.1.4458.1000.1.5.9.
1
Integer
RO
Received
Signal
Strength
in
dBm.
Relevant
only
for
point
to
point
systems.
winlink1000OduAirTotalFrames
1.3.6.1.4.1.4458.1000.1.5.9.
2
Counter
RO
Total
number
of
radio
frames.
winlink1000OduAirBadFrames
1.3.6.1.4.1.4458.1000.1.5.9.
3
Counter
RO
Total
number
of
received
radio
frames
with
CRC
error.
The
value
is
relevant
only
for
point
to
point
systems
.
winlink1000OduAirCurrentRate
1.3.6.1.4.1.4458.1000.1.5.9.
4
Integer
RO
Deprecated
parameter.
Actual
rate
of
the
air
interface
in
Mbps.
For
Channel
Bandwidth
of
20
10
5
MHz
divide
the
value
by
1
2
4
respectively.
winlink1000OduAirCurrentRateIdx
1.3.6.1.4.1.4458.1000.1.5.9.
5
Integer
RO
Index
of
current
air
rate.
winlink1000OduAirChainsRxPower
RO
Received
Signal
Strength
of
Cpe
chains
in
dBm.
Chain
1
RSS:
(1
Byte)
Chain
2
RSS:
(1
Byte)
Chain
3
RSS:
(1
Byte)
winlink1000OduAirTxPower36
1.3.6.1.4.1.4458.1000.1.5.1
0
Integer
RW Deprecated
parameter.
Actual
behavior
is
read
‐
only.
winlink1000OduAirTxPower48
1.3.6.1.4.1.4458.1000.1.5.1
1
Integer
RW Deprecated
parameter.
Actual
behavior
is
read
‐
only.
winlink1000OduAirCurrentTxPower 1.3.6.1.4.1.4458.1000.1.5.1
2
Integer
RO
Current
Transmit
Power
in
dBm.
This
is
a
nominal
value
while
the
actual
transmit
power
includes
additional
attenuation.
winlink1000OduAirMinFrequency
1.3.6.1.4.1.4458.1000.1.5.1
3
Integer
RO
Minimum
center
frequency
in
MHz.
winlink1000OduAirMaxFrequency
1.3.6.1.4.1.4458.1000.1.5.1
4
Integer
RO
Maximum
center
frequency
in
MHz.
winlink1000OduAirFreqResolution
1.3.6.1.4.1.4458.1000.1.5.1
5
Integer
RO
Center
Frequency
resolution.
Measured
in
MHz
if
value
<
100
otherwise
in
KHz.
winlink1000OduAirCurrentFreq
1.3.6.1.4.1.4458.1000.1.5.1
6
Integer
RO
Current
Center
Frequency.
Measured
in
MHz
if
center
frequency
resolution
value
<
100
otherwise
in
KHz.
winlink1000OduAirNumberOfChan
nels
1.3.6.1.4.1.4458.1000.1.5.1
7
Integer
RO
Number
of
channels
that
can
be
used.
winlink1000OduAirChannelsTable
N/A Table
of
channels
used
by
automatic
channels
selection
(ACS).
winlink1000OduAirChannelsEntry
N/A ACS
channels
table
entry.
INDEX
{
winlink1000OduAirChannelsIndex
}
winlink1000OduAirChannelsIndex
RO
Channel
Index.
winlink1000OduAirChannelsFreque
ncy
RO
Channel
frequency
in
MHz.
winlink1000OduAirChannelsOperSt
ate
RW Channel
state.
Can
be
set
by
the
user.
Automatic
Channel
Selection
uses
channels
that
are
AirChannelsOperState
enabled
and
AirChannelsAvail
enabled.
A
change
is
effective
after
link
re
‐
synchronization.
Valid
values:
disabled
(0)
enabled
(1).
Rewriteable
only
in
Point
‐
To
‐
Point
products.
winlink1000OduAirChannelsAvail
RO
Channel
state.
Product
specific
and
cannot
be
changed
by
the
user.
Automatic
Channel
Selection
uses
channels
that
are
AirChannelsOperState
enabled
and
AirChannelsAvail
enabled.
Valid
values:
disabled
(0)
enabled
(1).
winlink1000OduAirChannelsDefault
Freq
RO
Default
channel's
availability
for
all
CBWs.
The
valid
values
are:
forbidden
(0)
available
(1).
Table
C
‐
2:
Private
MIB
Parameters
‐
HBS
(Sheet
6
of
33)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 5000 HPMP
Page 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Page 21: ...Part 1 Basic Installation Release 3 5 70...
Page 69: ...Part 2 Sector Installation Release 3 5 70...
Page 155: ...Part 3 Sector Management Release 3 5 70...
Page 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Page 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Page 290: ...Part 4 Site Synchronization Release 3 5 70...
Page 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Page 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Page 354: ...Part 6 Field Installation Topics Release 3 5 70...
Page 396: ...Part 7 Product Reference Release 3 5 70...
Page 517: ......