SNC 450x User’s Guide
93
set MinOpTemp [temperature]
The
set MinOpTemp
command sets the minimum internal operating temperature of the SNC in degrees
Celsius. If the internal temperature of the SNC falls below the minimum operating temperature, thermal
control event handling occurs. Valid values are from 0 to 15. The default setting is “0." Refer to
get
MinOpTemp
on page 71.This command must be followed by
saveConfiguration restart
.
Ready.
set minoptemp 5
Ready.*
set OpTempWarn [temperature]
The
set OpTempWarn
command sets the number of degrees Celsius before a thermal control event warns
you if the SNC is approaching the minimum or maximum internal operating temperature. The warning is sent
to the system log. Valid values are from 0 to 15. The default setting is “5." Refer to
set OpTempWarn
[temperature]
. This command must be followed by
saveConfiguration restart
.
Ready.
set optempwarn 5
Ready.*
set Password
The
restoreConfiguration default
command sets the password to the default value “Password."
Passwords are case sensitive. They can be from 1 to 35 characters long, with no spaces. When the
password is empty, Telnet and FTP do not validate the password. To create an empty password, do not
type an answer to the
password
command confirmation prompts.
The following is an example of the input and output for the
set Password
command. Enter the old
password. In the example below, the old password is “Password.” Type in the new password at the
New
Password
prompt. Re-enter the password at the
Confirm New Password
prompt. Neither entry displays
on the screen. This command must be followed by
saveConfiguration norestart
.
Ready.
set password
Old Password: Password
New Password:
Confirm New Password:
Your password has been changed.
Ready. *
CAUTION
Contact ATAC before using this command.
Valid Temperature Values
0-15
CAUTION
Contact ATAC before using this command.
Temperature Valid Values
0-15
Summary of Contents for SNC 4500
Page 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Page 6: ...vi Contents...
Page 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Page 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Page 30: ...24 Getting Started...
Page 46: ...40 Using the SNC Manager Interface...
Page 112: ...106 Removal and Replacement Procedures...
Page 116: ...110 iSCSI Performance Tuning...
Page 119: ...SNC 450x User s Guide 113 BSMI Notice...
Page 120: ...114 Regulatory Notices...