SNC 450x User’s Guide
75
Ready.
get SNTPserver
5
;SNTP Server IP Addresses
;========================
192.43.244.18
129.6.15.28 AUX
132.163.4.101 AUX
Ready.
get SpeedWrite SCSI [bus target LUN]
The
get SpeedWrite [sb st sl | all]
command shows whether or not SpeedWrite has been enabled for a
specific SCSI bus (sb), target (st), and LUN (sl) or for all currently mapped SCSI devices on the SNC. For
an explanation of the SpeedWrite capability, refer to
set SpeedWrite SCSI [sb st sl | all] [status]
on page 98.
Ready.
get speedwrite scsi all
9
;sb st sl speedWrite State
0 1 0 disabled
0 2 0 disabled
0 3 0 disabled
0 4 0 disabled
1 0 0 disabled
1 1 0 disabled
1 2 0 disabled
1 3 0 disabled
Ready.
get SpeedWriteDefault
CAUTION
Contact ATAC before using this command.
Parameter
Meaning
sb
SCSI bus
st
SCSI target
sl
SCSI LUN
all
all currently-mapped devices
Output
Meaning
enabled
Provides enhanced performance of WRITE commands
disabled
Retains the current level of performance of WRITE commands
CAUTION
Contact ATAC before using this command.
Summary of Contents for SNC 4500
Page 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Page 6: ...vi Contents...
Page 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Page 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Page 30: ...24 Getting Started...
Page 46: ...40 Using the SNC Manager Interface...
Page 112: ...106 Removal and Replacement Procedures...
Page 116: ...110 iSCSI Performance Tuning...
Page 119: ...SNC 450x User s Guide 113 BSMI Notice...
Page 120: ...114 Regulatory Notices...