SNC 450x User’s Guide
83
Restart is necessary...
Do you wish to restart (y/n)? y
Restarting...]
Ready.
SCSIPortList
The
SCSIPortList
command outputs available SCSI ports and their current status. Valid status values are
“O.K.” and “failed." This command takes effect immediately.
Ready.
scsiportlist
4
;SCSI Port
Port Status
;========================
0
O.K.
1
O.K.
Ready.
SCSIPortReset [port number]
The
SCSIPortReset
command resets the specified SCSI bus. This command takes effect immediately.
Ready.
scsiportreset 0
Resetting Port Number 0
Ready.
SCSITargets [port number]
The
SCSITargets
command displays a list of SCSI devices operational on the referenced SCSI port. This
command takes effect immediately.
The following shows the information which is presented after a
SsciTargets 0
command:
Ready.
scsitargets 0
1
;
sb
st
sl
Device Type
Vendor ID
Product ID Rev. Serial Number
Ready.
set BridgeName
The
set BridgeName
command assigns a name to the SNC to identify a particular SNC. A
saveConfiguration restart
command must be used to permanently save this configuration.
Port Number
Meaning
0 or 1
SCSI connection labeled SCSI port 0 or SCSI port 1
Port Number
Meaning
0 or 1
SCSI connection labeled SCSI port 0 or SCSI port 1
Note
The
set BridgeName
command does not set the network name. It sets an
internal name for your SNC 450x.
Summary of Contents for SNC 4500
Page 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Page 6: ...vi Contents...
Page 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Page 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Page 30: ...24 Getting Started...
Page 46: ...40 Using the SNC Manager Interface...
Page 112: ...106 Removal and Replacement Procedures...
Page 116: ...110 iSCSI Performance Tuning...
Page 119: ...SNC 450x User s Guide 113 BSMI Notice...
Page 120: ...114 Regulatory Notices...