Management Port Command Reference
set DPMTU [port number] [MTU choices]
The
set DPMTU
command controls the MTU (Maximum Transmission Unit) used by the SNC data ports.
Increasing the MTU on the SNC can improve throughput on the SNC data ports. The host MTU must be
changed to match the SNC value in accordance with manufacturer’s instructions. This command must be
followed by
saveConfiguration restart
.
The MTU for the management port cannot be changed. The default setting is ”1514.” A
saveConfiguration
restart
command must be used to permanently save this configuration. Refer to
iSCSI Performance Tuning
on page 107 and
get DPMTU [port number]
on page 65.
The following example sets the Ethernet data port 0 to MTU 1514.
Ready.
set DPMTU dp0 1514
Ready.*
set EthernetSpeed [port number] [speed]
The
set EthernetSpeed
command controls the speed of the SNC Ethernet ports.
Refer to
iSCSI Performance Tuning
on page 107. If auto is enabled, the speed is negotiated. When hard
set, 10 and 100 speeds are half duplex. The default setting is “auto." A
saveConfiguration restart
command must be used to permanently save this configuration. Refer to
get EthernetSpeed [port number]
on page 66.
CAUTION
Increasing the MTU can improve performance. To fully understand the
implications and network requirements, contact your service
representative before modifying this value.
Port Number
Meaning
dp0 or dp1
Ethernet connection labeled Ethernet port 0 or Ethernet port 1
all
All Ethernet data ports
MTU Choices
1514
9014
16128
CAUTION
Contact ATAC before using this command.
Port Number
Meaning
mp0
Ethernet management port labeled Ethernet port 2
dp0 or dp1
Ethernet data port labeled Ethernet port 0 or Ethernet port 1
all
All Ethernet port connections
Summary of Contents for SNC 4500
Page 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Page 6: ...vi Contents...
Page 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Page 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Page 30: ...24 Getting Started...
Page 46: ...40 Using the SNC Manager Interface...
Page 112: ...106 Removal and Replacement Procedures...
Page 116: ...110 iSCSI Performance Tuning...
Page 119: ...SNC 450x User s Guide 113 BSMI Notice...
Page 120: ...114 Regulatory Notices...