83
SNC4000 > fcShow
------------------Fibre Channel Controllers-----------------------
Ctlr : PCI Addr : ISP : Firmware : Firmware : Loop : Fabric :
Port : E
xt. : Link
Id : Bs Dv Fn : Type : State : Version : ID : Attached : Mode : F
IFO : Speed
------------------------------------------------------------------
1 : 00 07 00 : 2300 : Sync Lost : 3.00.25 : None : No : Targ : N
one : 1 Gbps
2 : 00 08 00 : 2300 : Sync Lost : 3.00.25 : None : No : Targ : N
one : 2 Gbps
------------------------------------------------------------------------
------
value = 95 = 0x5f = ‘_’
value = 95 = 0x5f = '_'
Ctlr Id
Indicates the Port Number for this interface.
PCI Addr
The PCI address of the interface, showing bus, device id, and function number.
ISP Type
The type of FC Controller.
Firmware State
The current state of the interface as reported by the FC controller. Firmware states are
listed below.
Configuration Wait
Firmware is not initialized.
Waiting for AL_PA
Firmware is performing or waiting to perform loop initialization.
Waiting for login
Firmware is attempting port and process logins with all loop ports.
Ready
Indicates that the interface is connected and operational and ready to process SCSI
commands. Any other value indicates intermediate states or interface failure.
Sync Lost
The firmware has detected a loss-of-sync condition and is re-synchronizing the serial
link receiver. This is the state reported when the FC link does not detect a connection
to a FC device.
Error
The firmware has detected an unrecoverable error condition.
Nonparticipating
The firmware is not participating on the loop since it did not acquire an AL_PA during
initialization.
Failed
The firmware is not responding to commands.
Firmware Version
The version of firmware on the FC controller.
Loop ID
The FC Loop ID for this interface. PtoP indicates a point-to-point connection.
Fabric Attached
Indicates whether the port is attached to a Fabric.
Port Mode
Indicates whether the port is set to Target or Initiator mode
Ext. FIFO
Indicates that FIFOs external to the FC controller are on the board. If they are, their
size in KB will be output into this column.
Link Speed
Indicates the actual speed of the connection. This figure is only meaningful when the
Firmware State is reported as
Ready
.
2
displays the information included at levels 0 and 1, and appends
loop ID link stats
Level
Meaning
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...