SNC 4000 User’s Guide
131
---- --- ------- ---- -- --- ------ ------- --------
1 0 0 0 0 0 ADIC Scalar SNC 4134 600613
1 1 1 4 5 0 ADIC Scalar 1000 3.01 123456789
1 2 2 4 6 0 ADIC Scalar 1000 3.00 123444789
1 4 4
1 6 3 4 6 1 ADIC Scalar 1000 3.00 123455589
value = 0 = 0x0
SNC >
vpsMapClear [index]
The
vpsMapClear
command clears all of the mapping assignments for the host specified by
[index]
.
vpsMapDelete [devID] [hostIndex] [lun]
The
vpsMapDelete
command deletes a previous LUN assignment. If the deletion is successful, the value
0
is output. If the deletion fails, the value
-1
is output. In the example below, the deletion was successful.
To verify the effects of the
vpsMapDelete
command, issue the
vpsMapShow [hostIndex]
command.
SNC > vpsMapDelete 1,3
value = 0 = 0x0
SNC > vpsMapShow
Host Lun Internal Chan Id Lun Vendor Product Rev SN
---- --- ------- ---- -- --- ------ ------- --------
1 0 0 0 0 0 ADIC Scalar SNC 4134 600613
1 1 1 4 5 0 ADIC Scalar 1000 3.01 123456789
1 2 2 4 6 0 ADIC Scalar 1000 3.00 123444789
1 4 4
value = 0 = 0x0
SNC >
vpsMapShow [hostIndex]
The
vpsMapShow
command lists all available eVPS mapping information for a host. If no host is specified
then the device maps for all hosts are listed.
SNC > vpsMapShow
Host Lun Internal Chan Id Lun Vendor Product Rev SN
---- --- ------- ---- -- --- ------ ------- --------
1 0 0 0 0 0 ADIC Scalar SNC 4134 600613
1 1 1 4 5 0 ADIC Scalar 1000 3.01 123456789
1 2 2 4 6 0 ADIC Scalar 1000 3.00 123444789
1 4 4
value = 0 = 0x0
SNC >
vpsNameSet [hostIndex],"name string"
The
vpsNameSet
command sets the host name field to the specified “name string” for the specified host
connection index. The following command example shows setting the host name for host ID 1 to
“LANDERS”. Existing hostIndex and name values can be determined by looking at the "Id" and "Host Name"
columns in the output of the
sfmShow -1
command.
SNC > vpsNameSet 1,"LANDERS"
value = 0 = 0x0
SNC >
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...