Service Port Command Reference
SNC4000 > envMonRangeShow
Air Inlet Temp (C):
Nominal: 5 to 45
Warning: 4 <= N < 5 or 45 < N <= 50
Alarm: N < 4 or N > 50
Air Outlet Temp (C):
Nominal: 5 to 50
Warning: 4 <= N < 5 or 50 < N <= 55
Alarm: N < 4 or N > 55
IO Processor Temp (C):
Nominal: 5 to 80
Warning: 4 <= N < 5 or 80 < N <= 108
Alarm: N < 4 or N > 108
Input Power: +5 Volts (V):
Nominal: 4.94 <= N <= 5.36
Warning: 4.84 <= N < 4.94 or 5.36 < N <= 5.46
Alarm: N < 4.94 or N > 5.46
Input Power: +12 Volts (V):
Nominal: 11.00 to 12.93
Warning: 10.75 <= N < 11.00 or 12.93 < N <= 13.18
Alarm: N < 10.75 or N > 13.18
Local Power: +2.5 Volts (V):
Nominal: 2.42 to 2.58
Warning: 2.36 <= N < 2.42 or 2.58 < N <= 2.62
Alarm: N < 2.36 or N > 2.62
Local Power: +3.3 Volts (V):
Nominal: 3.20 to 3.39
Warning: 3.13 <= N < 3.20 or 3.39 < N <= 3.46
Alarm: N < 3.13 or N > 3.46
Fan :
Nominal: 1; Alarm: 0
value = 1 = 0x1
ethAddrGet
The
ethAddrGet
command displays the IP address of the SNC 4000, specified as 4 decimal numbers
separated by periods.
SNC4000 > ethAddrGet
IP Address set to 192.168.1.176
value = 0 = 0x0
ethAddrSet
The
ethAddrSet
command changes the IP address of the SNC 4000. An IP address is specified as 4
decimal numbers separated by periods.
SNC4000 > ethAddrSet "192.168.1.54"
Host Address set to 192.168.1.54 for Ethernet interface
value = 0 = 0x0
If a netmask is required, specify it after the IP address in “dotted decimal” form. For example:
SNC4000 > ethAddrSet "10.0.0.2","255.255.0.0"
Inet Mask set to ffff0000 for Ethernet interface
Write complete
Host Address set to 10.0.0.2 for Ethernet interface
value = 0 = 0x0
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...