SNC 4000 User’s Guide
129
vpsHostInbandAccessSet 1,[setting]
The
vpsHostInbandAccessSet
command sets the default access level for in-band API commands for a
particular host. After you have made the setting, check the results with
vpsHostInbandAccessGet
[hostIndex],1
.
The default access level is 5, self-read and self-write access only.
SNC > vpsHostInbandAccessSet 1,7
value = 0 = 0x0
SNC > vpsHostInbandAccessGet 1,1
Read Access:
Self: 1, 3rd Party: 1
Write Access:
Self: 1, 3rd Party: 0
value = 7 = 0x7
To view the in-band access level for a particular host, use the
vpsHostInbandAccessGet [hostIndex],1
command.
vpsHostShow [hostIndex]
The
vpsHostShow
command displays all known VPS or eVPS information for the specified host connection
index. The LUN access map is displayed as 16 rows of 16 bytes, one byte for each LUN.
The following command example shows VPS or eVPS information for host ID 1.
SNC > vpsHostShow 1
Host(1):
Value
Meaning
1
Self-read
2
3rd-Party read
3
Self-read + 3rd-Party read
4
Self-write
5
Self-read + Self-write
7
Self-read + 3rd-Party read + Self-write
8
3rd Party write
10
3rd-Party read + 3rd-Party write
11
3rd-Party read + 3rd-Party write + Self-read
14
3rd-Party read + 3rd-Party write + Self-write
15
Self-read + 3rd-Party read + Self-write + 3rd Party write
Parameter
Value
Meaning
hostIndex
is the Id obtained from the
sfmShow
command.
[LUN]
00
in the LUN Access map indicates the host has no
access to the LUN.
01
in the LUN Access map indicates the host has
access to the LUN.
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...