SNC 4000 User’s Guide
15
Figure 5
SCSI Cabling for Two Drives
8
Turn on the Scalar 24.
Within one minute, the RDY LED on the SNC should start flashing once per second and the
Done
executing startup script
message should be displayed on the service terminal.
9
Configure the network information by typing the following at the service terminal:
ethAddrSet "ip_address","subnet_mask"
where
“ip_address”
and
“subnet_mask”
are replaced with actual values, for example:
ethAddrSet “172.16.32.12”,“172.16.1.1
”
Then enter:
gateAddrSet "default_gateway_ip"
where
“default_gateway_ip”
is replaced with the default gateway IP address.
Then enter:
hostNameSet "name"
where
“name”
is replaced with the name you would like displayed in the ADIC Management Console.
10
Configure the date and time. You can either set the real time clock manually, or use a timeserver. Refer
to the procedures below to set the date and time.
Setting the Time and Date
Follow the procedure below to set the Real Time Clock (RTC). For more information on the commands used
in this procedure, see
Commands Listed Alphabetically by Function
on page 63.
1
Use the
rtcDateSet
command to manually set the Real Time Clock. The
rtcDateSet
command
takes the following arguments:
[year],[month],[day_of_month],[day_of_week],[hour],[minute],[second]
For example:
SNC4000 > rtcDateSet 2001,1,26,5,9,30,00
2
Use the
dateSetFromRTC
command to set the RTC as the source of date display:
SNC4000 > dateSetFromRTC
value = 0 = 0x0
3
Use the
tzSet
command to set the time zone. EST is used in the example for Eastern Standard Time:
SNC4000> tzSet "EST"
TZ Set TIMEZONE = EST:EDT:300:040202:101502
value = 0 = 0x0
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...