40
Maintenance Action Plans
64
4
1
1
Outlet Air Temperature or I/O Processor
Temperature has entered Warning Range
from Nominal or Alarm Ranges
4
65
1
1
Outlet Air Temperature or I/O Processor
Temperature has entered Alarm Range
4
66
1
1
Fan is operating in Nominal Range after
operating in a fault state
0
67
1
1
Fan speed has entered Warning Range
(Tachometer fans only)
4
68
1
1
Fan speed has entered Alarm Range
(Tachometer fans) or is stalled (rotor stall
fans)
4
70
5
1
1
Firmware upload completed
0
71
5
1
1
SNC restart completed
0
72
1
1
Maximum number of initiators has been
exceeded
0
75
1
1
Connectivity with the host has been lost.
2
76
1
1
Connectivity with the host has been
established.
0
150
1
1
The event log is about to overwrite the
earliest events
0
Health Check Event Descriptions
100
1
1
Power supply is out of specification
5
102
1
Temperature change detected since the last
report (event message indicates the change
to High, Very High, Reduced to High, or OK)
4, 0
106
1
1
FC interface failed Health Check
2
107
1
1
SCSI interface failed Health Check
1
109
1
1
Target device failed Health Check
1
110
1
1
FC link status changed
0, 2
111
1
1
FC transfer failures detected since the last
report
CAUTION: error recovery may have
succeeded
0
112
1
1
Blower/Fan is running in Warning or Alarm
Range
4
113
1
1
Power is running in Warning or Alarm Range
5
Table 4
Event Codes and Actions
Event
Code
Viewing
Level
1
Default Trap
Threshold
Description
Action
2
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...