130
Service Port Command Reference
State = 0, Type = 1, Flags = 0x00000000, Online
WWN: 200000e0:8b0057d8
Name: 'LABATTS'
Host Type: 'NT 4.0 SP5'
Device Id: 'ScsiPort6 [0:0:0] (QLA2100)
LUN Access:
0: 01 01 01 00 00 00 00 00 00 00 00 00 00 01 01 00
16: 00 00 00 00 00 00 00 00 00 01 01 00 00 00 00 00
32: 00 00 00 00 00 01 01 00 00 00 00 00 00 00 00 00
48: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
64: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
96: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
112: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
128: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
144: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
160: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
176: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
192: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
208: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
224: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
240: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
value = 0 = 0x0
SNC >
vpsInactiveSet
The
vpsInactiveSet
command de-activates VPS or eVPS making all LUNs available to all host
connections. This command typically would be used when troubleshooting a SAN configuration. It removes
eVPS access control without deleting VPS or eVPS access settings. Use the
sfmActiveSet
command to
re-activate VPS or eVPS.
SNC > vpsInactiveSet
value = 0 = 0x0
SNC >
If VPS or eVPS is already inactive, the following is displayed.
SNC > vpsInactiveSet
VPS: Already Inactive
value = 23 = 0x17
SNC >
vpsMapAdd [devID] [hostIndex] [lun]
The
vpsMapAdd
command assigns a target device (
devId
) to a host (
hostIndex
) with the specified
Logical Unit Number of (
lun
). If the assignment is successful, the value
0
is output. If the assignment fails,
the value
-1
is output. In the example below, the assignment was successful.
Device ID can be determined by finding the device in the list generated by
mapShowDevs
.
Existing hostIndex values can be determined by looking at the "ID" column in the output of the
sfmShow
[hostIndex]
command.
To verify the effects of the
vpsMapAdd
command, issue the
vpsMapShow [hostIndex]
command.
SNC > vpsMapAdd 1,6,3
value = 0 = 0x0
SNC > vpsMapShow
Host Lun Internal Chan Id Lun Vendor Product Rev SN
Summary of Contents for SNC 4000
Page 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Page 10: ...4 SNC 4000 Introduction...
Page 40: ...34 Removal and Replacement Procedures...
Page 140: ...134 Service Port Command Reference...
Page 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Page 148: ...142 Diagnostic Command Reference...