70
6
2
3
86
81
Assembly of Rail Connector
SRU/LPS
Enclosure Post Version 1:
The Climbing Rail-2 LPS (2) is extended
by means of a Rail Connector SRU/LPS
(6) with the Steel Waler Universal SRU
(3).
1. Insert Rail Connector SRU/LPS (6) into
the Climbing Rail LPS (2).
2. Insert 2x Fitting Pins Ø 21x120 (81)
and Cotter Pins 4/1 (86) through holes
Ø 21 to secure Rail Connector.
3. Position the Steel Waler Universal (3)
on the Rail Connector SRU/LPS, and
secure by means of a further 2x Fit-
ting Pins Ø 21 and 4/1 Cotter Pins in-
serted through the Ø 21 holes.
(Fig. C1.05 + C1.06)
– When mounting Steel Walers Univer-
sal SRU that are longer than those
specified in the standard configura-
tion, the static load-bearing capacity
of the Rail Connector for wind loads
and load case erection must be veri-
fied.
– The Slab Anchor Template LPS cannot
be mounted on the Steel Waler Uni-
versal.
Note
The SRU profile (3) does not fit in the
Rail Guidance Shoe LPS.
The Fitting Pins (81) in the Climbing Rail
collide with the guiding skids of the Rail
Guidance Shoe.
This can cause damage to the climbing
enclosure and reduce the load-bearing
capacity of the anchoring.
⇒
⇒
Always install and close the Rail Guid-
ance Shoe below the Rail Connector.
Components
2
Climbing Rail-2 LPS
2.1
Spacer LPS 52
3
Steel Waler Universal SRU
6
Rail Connector SRU/LPS
81
Fitting Pin Ø 21x120
86
Cotter Pin 4/1
C1 Pre-Assembly
Fig. C1.05
Fig. C1.06
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration