58
10
11
22a
28
28
22a
22
22
3
6
0 m
m - 7
5
0 m
m
375 mm - 825 mm
2
0
0 m
m
200 mm
B3 Corner Platforms
Corner elements with building
column
For small, rectangular building columns
at the corner of the building, a overlap-
ping arrangement of the corner ele-
ments might be required.
At the corner of the building: a cross-
wise arrangement of the Slab Shoe-2
LPS (10) and Slab Shoe Corner-2 LPS
(11).
On the front sides of the working plat-
form, connect the Telescopic Screen
(22) with the Screen Adapter Corner
LPS (28) to the Telescopic Screen (22a)
on the outside.
(Fig. B3.04)
Cover remaining gaps.
– This version is not covered by the
standard assembly. Additional static
proof for wind loads parallel to the
edge of the building must be provid-
ed.
– If necessary, a horizontal support is to
be dimensioned and arranged parallel
to the edge of the slab.
– In this case, it is not possible to pass
around the corner.
Components
10
Slab Shoe-2 LPS
11
Slab Shoe Corner-2 LPS
22
Telescopic Screen DX LPS
28
Screen Adapter Corner LPS
Fig. B3.04
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration