128
90.6
90.1
2.1
D5 Moving with the Climbing Device
Step 9
1. Completely retract all hydraulic cylin-
ders:
– Load is carried by the climbing pawl
in the middle Slab Shoe (10b),
– Claw (90.1) is released from the
Spacer (2.1).
2. Detach hydraulic hoses from the
climbing device using the quick cou-
plers.
3. Close the Foldable Covers (40).
4. Tilt the climbing device backwards,
operate the locking lever (90.6) on the
cylinder base and lift out the climbing
device. (Fig. D5.09)
5. Transport the hydraulic pump, climb-
ing device and hydraulic hoses to the
next climbing enclosure.
In order to prevent the locking lever im-
mediately engaging again after releas-
ing, press the climbing device slightly to
the side.
When the hydraulic cylinders are
not being used, always completely re-
tract the pistons.
Components
10.2
Climbing Pawl
90.1
Claw
90.6
Locking Lever
Fig. D5.09
LPS Screen Lightweight Climbing Enclosure