28
4
4
33
33
2
2
21
21
h
B
2.50 m
5.00 m
LPS 748 + 398
7.11 m
2.23 m
3.00 m
6.00 m
LPS 748 + 398
8.36 m
2.23 m
3.50 m
7.00 m
LPS 748 + 398
9.61 m
2.23 m
4.00 m
8.00m
LPS 998 + 398
10.86 m
2.23 m
4.50 m
9.00 m
LPS 998 + 398
12.11 m
2.23 m
h
S
B1 Planning the Supporting Structure
Version 2
For screens with working platform, the
climbing rail limits the possible storey
height.
The distance h
S
to the bottom edge of
the slab reduces the projecting length h
1
and has to be selected depending on the
slab formwork system.
PERI recommends for
SKYDECK
hS ≥ 0.50 m
GRIDFLEX
hS ≥ 0.50 m
MULTIFLEX
hS ≥ 0.60 m
For Version 2, the following is consid-
ered as standard:
Climbing Rail LPS 748 or 998 (2) in con-
nection with platform (33) and Climbing
Rail LPS 398 (4) as enclosure post.
As a result, a protection height of 7.11 m
to 12.11 m is possible.
Other Version 2 combinations are not
covered by the standard configuration
and require static verification, as well as
site-specific assembly instructions.
Components
2
Climbing Rail-2 LPS 748 or 998
4
Climbing Rail-2 LPS 398
21
Screen Element DX LPS
33
Platform LPS
5
,2
3 m
4
,7
3
m
2
,2
3 m
2
,2
3 m
3
,0
0 m
2
,5
0 m
3
,0
0 m
2
,5
0 m
8
,3
6 m
7,
11
m
Fig. B1.09
Fig. B1.10
h
B
= 2,50 m
h
B
= 3,00 m
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration
Version 2 – climbing rails dependent on storey height h
B
max h
B1
+ h
B2
*
Climbing Rail
Screen Element
Protection height in total Projection h
1
3 + 3 rows
4 + 3 rows
5 + 3 rows
6 + 3 rows
7 + 3 rows
Table B1.02
* 2 x storey height / largest dimension of two consecutive storeys.
** for hS = 50 cm