56
2
10
11
B3 Corner Platforms
External Corners
When planning all corner solutions en-
sure that the mesh panel enclosure on
the climbing rail does not collide with
the platform of the neighbouring unit
during climbing.
If there is a risk of the platforms colliding
with the mesh panels of the neighbour-
ing unit during climbing, then the climb-
ing sequence has to be specified during
planning and has to be pointed out ex-
plicitly during the briefing and introduc-
tion.
Corner area 90°
Standard corner elements e.g. for inter-
nal building columns with an edge dis-
tance of x ≥ 400 mm.
At the corner of the building: a cross-
wise arrangement of the Slab Shoe-2
LPS (10) and Slab Shoe Corner-2 LPS
(11). (Fig. B3.01a)
For a load-optimised corner solution,
arrange the Slab Shoes as close to the
building corner as possible.
Going below a lateral edge distance c
2
of
200 mm for the anchoring is not advisa-
ble without additional static proof.
If necessary, measure and arrange edg-
ing reinforcement in the slab.
Components
10
Slab Shoe-2 LPS
11
Slab Shoe Corner-2 LPS
Fig. B3.01
Fig. B3.01a
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration