31
2.1
2
5
0 c
m
12
5
m
m
B1 Planning the Supporting Structure
Additional Spacers
On the climbing rails, spacers are
mounted at a distance of 50 cm.
Additional spacers (2.1) can be installed
on the climbing rail (2).
This allows the height of the climbing
enclosure to be adjusted in increments
of 125 mm.
(Fig. B1.15)
Spacers are used for supporting the
climbing enclosure on slab shoes during
working operations.
PERI recommends mounting an addi-
tional Spacer LPS 52 for standard storey
heights that are multiples of 50 cm.
This ensures a definite bearing on the
planned slab shoe without having to de-
activate the other slab shoes.
Fig. B1.15
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration