111
13.5
13.5
13.9
13.7
13.9
Anchoring M24 Version 3
Climbing Cone-2 M24/DW 15 (13.5)
partially re-usable.
1. Release Climbing Cone by means of
socket wrench SW 36 and remove.
2. Close remaining hole with suitable KK
Concrete Cone (13.9) and adhesive.
(Fig. D1.12c)
Warning
During dismantling, anchoring compo-
nents may fall to the ground and hit peo-
ple below. This could lead to serious in-
juries or even death.
⇒
⇒
Cordon off areas of risk under the
working areas.
⇒
⇒
In order to prevent personnel falling
out of the building, use a guardrail un-
derneath with a dense mesh, e.g.
PROKIT.
Anchoring M24 Version 4
Climbing Cone-2 M24/DW 15
completely re-usable.
1. Loosen Climbing Cone (13.5) using a
socket wrench SW36 and screw out
approx. 1 cm.
2. Hammer cone down so that the
Threaded Anchor Plate DW 15 (13.7)
is loosened.
3. Now completely remove the Cone.
Remove the Threaded Anchor Plate
together with Tie Rod DW 15 from be-
low using a secured mobile scaffold.
4. Close remaining hole with suitable KK
Concrete Cone (13.9) and matching
adhesive.
(Fig. D1.12d)
Components
13.5
Climbing Cone-2 M24/DW 15
13.7
Threaded Anchor Plate DW 15 Ø
80 mm
13.9
KK Concrete Cone M24
D1 Suspension and Anchoring
Fig. D1.12d
Fig. D1.12c
LPS Screen Lightweight Climbing Enclosure