B2 Planning the Units
Covering with Finishing Plat-
form
Instead of foldable covers, Trailing Plat-
forms LPS can be mounted for securing
the gap between the enclosure and the
slab edge.
Version 1 + 2
For the climbing enclosure with working
platform, without cantilevered slab shoe,
the gap is completely covered by the
trailing platform.
Securing the slab edge
Mount Support Angle (51) on the Tele-
scope Beam by means of bolts (72) and
nuts (72.1) and pins (57) and cotter pins
(86).
Attach Platform Cover Trailing Platform
LPS (53, 54) to the Support Angle (51)
using oval-head screws (73).
When enclosing with the Telescopic
Screens, extend the telescopic tubes
(50.1) and close the gap with Support
Angles and Platform Cover LPS 92.
For Telescopic Screens that are only par-
tially extended, close the gap with cut-
to-size untreated plywood and screwed
on Cover Strip LPS 0.20 x 10 m.
(Fig. B2.14a)
The Platform Cover Trailing Platform (55,
56) can only be mounted on a retracted
telescopic tube (50.2). (Fig. B2.14)
Components
50
Telescope Beam Trailing Platform
LPS
51
Support Angle TP LPS 25
52
Cantilever TP LPS 57
53
Platform Cover TP LPS 92
54
Platform Cover Trailing Platform
LPS
55
Corner Cover Trailing Platform
LPS, left
56
Corner Cover Trailing Platform
LPS, right
57
Bolt Ø 16x36
72
Bolt ISO 4017 M16x40-8.8
72.1
Nut ISO 7040 M16-8
73
Oval-Head Screw ISO 7380
M10x25-10.9
73.1
Nut ISO 7040 M10-8
79
Untreated Plywood 20, 21 mm
86
Cotter Pin 4/1
Fig. B2.14
Fig. B2.14a
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration