A p p e n d i x D : P r o g r a m m i n g
D-69
AC890PX AC Drive
MOT PMAC PROTECT
SETUP::MOTOR CONTROL::MOT PMAC PROTECT
Designed for PMAC Control Mode.
This is a motor protection based on the rms current flowing in the motor phases. This protection is called I2T and is based on
the permanent current and thermal time constant.
The 100% permanent current is the following curve extracted from parameters in MOTOR PMAC 1 and 2 function block:
The rms motor current is filtered with a first order low pass filter based on the THERMAL TIME CST. The output I2T
MOTOR LOAD of this filter is a percentage of the motor thermal load. When this output exceeds 100%, the drive trips in I2T
MOTOR TRIP. The level of motor load (I2T MOTOR LOAD) is given as a percentage (100% represents a current equal to
the PERM CURRRENT flowing in the motor phases for a THERMAL TIME CST time).