D-10
A p p e n d i x D : P r o g r a m m i n g
AC890PX AC Drive
ANALOG OUTPUT
SETUP::INPUTS & OUTPUTS::ANALOG OUTPUT
The analog output blocks converts the demand percentage into a form suitable for driving the analog output electronics of the Drive.
Parameter Descriptions
VALUE
PREF: 6.01, 7.01,
Default: —.xx %
Range: -300.00 to 300.00 %
The demanded value to output.
TYPE
PREF: 6.05, 7.05
Default:0..+10V
Range: See below
The output hardware Voltage type. An incorrect selection will force the VALUE to be set to zero.
Enumerated Value
:
Type
0 : -10..+10 V
1 : 0..10 V
Functional Description
The Drive has two analog outputs. There is an ANALOG OUTPUT function block associated with each of these:
AOUT1 is associated with terminal X12/06
AOUT2 is associated with terminal X12/07
OUTPUT
VALUE
TYPE
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...