C h a p t e r 3 : I n s t a l l i n g t h e D r i v e
3-33
AC890PX AC Drive
SET-UP PARAMETERS
PREF
6911Display
Default
Brief Description
V/Hz
SV
CLV
4-Q PMAC
102.01 RUN STOP MODE
0 : RUN RAMP
1 : COAST
2 : DC INJECTION
3 : STOP RAMP
Selects the stopping mode
used by the drive
x x x
x
x
103.01 JOG SETPOINT
10.0 %
Drive speed setpoint whilst
jogging (percentage of
MAX SPEED)
x x x
x
x
21.01 V/F SHAPE
0 : LINEAR LAW
1 : FAN LAW
2 : USER DEFINED
Sets the type of volts to
frequency template that is
used to flux the motor
x
70.01 QUADRATIC
TORQUE
0 : FALSE
1 : TRUE
0 : FALSE = Constant
Selects between Constant
or Quadratic mode of
operation
x x x
x
27.05 MOTOR CURRENT product code dependent Enter the motor full load
current from the motor
nameplate
x x x
x
21.03 FIXED BOOST
product code dependent Boosts starting torque by
adding volts at low speed
x
82.01 CURRENT LIMIT
150.00%
Level of motor current as %
of FULL LOAD CALIB
x x x
x
81.01 VOLTAGE MODE
None
Defines how volts Hz
characteristic varies in
response to changes in DC
link voltage.
x x x
x
27.02 POWER
product code dependent Nameplate induction
motor power
x x x
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...