A p p e n d i x D : P r o g r a m m i n g
D-29
AC890PX AC Drive
Parameter Descriptions
SLOT2 FAULT
PREF: 136.13
Default: 0
Range: See below
This diagnostic defines the slot B error status
Enumerated Value
:
SLOT2 FAULT
0
:
NONE
No
error
1 : PARAMETER VALUE
The board has an error on an internal parameter
2 : TYPE MISMATCH
The defined type doesn’t match the type of board fitted
3 : SELFTEST
The board has a selftest error
4 : HARDWARE
There is a hardware error in the board
5 : MISSING
There is no board plugged in but one should be
SLOT2 VERSION
PREF: 136.14
Default: 0000
Range: 0000 to 9999
When a board is plugged in slot B, this diagnostic gives the board version number
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...