D-170
A p p e n d i x D : P r o g r a m m i n g
AC890PX AC Drive
Parameter Descriptions
CONTINUOUS
PREF: 118.08
Default: FALSE
Range: FALSE / TRUE
When TRUE, it forces a smooth transition if the speed point is changed when ramping. The curve is controlled by the ACCELERATION and
JERK 1 to JERK 4 parameters. When FALSE, there is an immediate transition from the old curve to the new curve.
HOLD
PREF: 118.09
Default: FALSE
Range: FALSE / TRUE
When TRUE, the output of the ramp is held at its last value.
SYMMETRIC JERK
PREF: 118.10
Default: FALSE
Range: FALSE / TRUE
When TRUE, JERK 1 is used for all segments of the curve. JERK 2, JERK 3 and JERK 4 are ignored.
RESET
PREF: 118.11
Default: FALSE
Range: FALSE / TRUE
If TRUE, the output is made equal to the input.
OFFSET
PREF: 118.12
Default: 0.0000 deg
Range: 0.0000 to 360.0000 deg
This input provides an additional offset to be applied to the Position Output
MAX SPEED
PREF: 118.18
Default: 1500.0 rpm
Range: 100.0 to 6000.0 rpm
This parameter specifies the maximum speed of the Virtual Master
POSITION OUTPUT
PREF: 118.14
Default: —.xxxx deg
Range: —.xxxx deg
Master position output.
SPEED OUTPUT
PREF: 118.13
Default: —.xx Hz
Range: —.xx Hz
Master speed output.
ACCEL OUTPUT
PREF: 118.15
Default: —.xx
Range: —.xx
Master acceleration output in /s^2.
RAMPING
PREF: 118.16
Default: FALSE
Range: FALSE / TRUE
This is set TRUE when ramping.
STATUS
PREF: 118.19
Default: 4
Range: See below
Operating status of the Virtual Master.
Enumerated Value
:
Status
0 : READY
operating correctly
1 : RESET
RESET input is FALSE
2 : DUPLICATE another VIRTUAL MASTER has the same CHANNEL number
3 : INITIALISING FireWire is present but state not yet known
4 : NO FIREWIRE No FireWire Option fitted or no FireWire power supplied
5 : DISABLED
CHANNEL set to zero
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...