A p p e n d i x D : P r o g r a m m i n g
D-49
AC890PX AC Drive
Parameter Descriptions
ACCEL OUTPUT
PREF: 119.08
Default: —.xx
Range: —.xx
This diagnostic shows the acceleration demand in load mechanical Hz/s (rev/s
2
).
MASTER POSITION
PREF: 119.09
Default: —.xxxx deg
Range: —.xxxx deg
This diagnostic shows the master aster position demand in mechanical degrees.
MASTER SPEED
PREF: 119.10
Default: —.xxxx Hz
Range: —.xxxx Hz
This diagnostic shows the master speed demand in mechanical Hz (rev/s).
MASTER ACCEL
PREF: 119.11
Default: —.xxxx
Range: —.xxxx
This diagnostic shows the master acceleration demand in mechanical Hz/s (rev/s
2
).
READY
PREF: 119.14
Default: FALSE
Range: FALSE / TRUE
This diagnostic is TRUE when local drive is properly synchronised with the master, i.e. Status = READY.
STATUS
PREF: 119.13
Default: 7
Range: See below
This diagnostic shows operating and error states
Enumerated Value
:
Status
0 : READY
the Firewire Ref is operating normally
1 : REF RESET
the FireWire Ref RESET is set TRUE
2 : MASTER RESET
the Virtual Master is in Reset
3 : LOST SYNC
time stamp difference to large
4 : DUP MASTER
more than one Virtual Master with the same channel
5 : MISSING MASTER no Virtual Master with selected channel
6 : NO FIREWIRE
no FireWire - either not fitted or no PHY power
7 : DISABLED
the FireWire CHANNEL is set to 0
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...