D-96
A p p e n d i x D : P r o g r a m m i n g
AC890PX AC Drive
PHASE MOVE
SETUP::PHASE CONTROL::PHASE MOVE
Performance Level = ADVANCED : CLOSED-LOOP VEC Motor Control Mode only.
The FireWire option card (Option B) must be fitted to the drive.
This function block uses a position loop to stop the drive in a set distance. The distance is set in revolutions based on the number of lines on the
encoder, usually from a mark at a fixed distance from the home position.
For accurate positioning the drive must be in Closed Loop Vector mode, if the drive is in any other mode then an open loop home algorithm will be
used.
Parameter Descriptions
ENABLE
PREF: 109.01
Default: FALSE
Range: FALSE / TRUE
If the function block is not already Active, ENABLE starts the Move operation when going from FALSE to TRUE. Setting ENABLE to FALSE
while a move is active will
NOT
abort the operation.
HOLD
PREF: 109.08
Default: FALSE
Range: FALSE / TRUE
Command to hold the current move. (In this state a new move may be triggered, replacing the held move)
RESET
PREF: 109.11
Default: FALSE
Range: FALSE / TRUE
When True, this input aborts the current Move, and if the position loop is not operating, resets the Offset to zero.
DISTANCE
PREF: 109.02
Default: 1.0
Range: -3000.0 to 3000.0
Sets the homing distance in revolutions, a revolution calculated from the number of lines on the encoder and maximum speed.
DISTANCE FINE
PREF: 109.03
Default: 0.0000
Range: -1.0000 to 1.0000
Fine adjustment of homing distance. The actual homing distance is the sum of DISTANCE and DISTANCE FINE.
VELOCITY
PREF: 109.04
Default: 1.00 %
Range: 0.10 to 300.00 %
The maximum velocity at which the distance is added to the phase loop, set in units per second.
ACCELERATION
PREF: 109.07
Default: 1.00 %
Range: 0.01 to 300.00 %
The acceleration at which the distance is added to the phase loop, set in units per second
2
.
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...