A p p e n d i x D : P r o g r a m m i n g
D-89
AC890PX AC Drive
OP STATION
SETUP::MENUS::OP STATION
This block allows the operation of the Keypad control keys to be customised.
Parameter Descriptions
ENABLED KEYS
PREF: 30.01
Default: 00F0
Range:
0x0000 to 0xFFFF
The following keys on the Keypad can be enabled or disabled separately. The combination produces the parameter setting as in the table below.
Parameter Setting
RUN
L/R
JOG
DIR
0000
0010
0020
0030
0040
0050
0060
0070
0080
0090
00A0
00B0
00C0
00D0
00E0
00F0
-
-
-
-
-
-
-
-
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
-
-
-
-
ENABLED
ENABLED
ENABLED
ENABLED
-
-
-
-
ENABLED
ENABLED
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
OP VERSION
PREF: 30.02
Default:0000
Range: 0x0000 to 0xFFFF
Displays the software version of the Keypad. It is cleared to 0x0000 if no Keypad is connected.
OP DATABASE
PREF: 30.03
Default: FALSE
Range: FALSE / TRUE
Reserved for SSD Drives.
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...