SRAMP DECEL
PREF: 100.08
Default: 10.0
Range: 0.00 to 100.00 /s²
This functions in the same way as SRAMP ACCEL above.
SRAMP JERK 1
PREF: 100.09
Default: 10.0
Range: 0.00 to 100.00 /s
3
Rate of change of acceleration for the first segment of the curve in units of percent per second³, i.e. if the full speed of the machine is 1.25m/s then
the jerk will be:
1.25 x 50.00% = 0.625m/s³
SRAMP JERK 2
PREF: 100.10
Default: 10.0
Range: 0.00 to 100.00 /s
3
Rate of change of acceleration in units of percent per second³ for segment 2.
SRAMP JERK 3
PREF: 100.11
Default: 10.0
Range: 0.00 to 100.00 /s
3
Rate of change of acceleration in units of percent per second³ for segment 3.
SRAMP JERK 4
PREF: 100.12
Default: 10.0
Range: 0.00 to 100.00 /s
3
Rate of change of acceleration in units of percent per second³ for segment 4.
HOLD
PREF: 100.13
Default: FALSE
Range: FALSE / TRUE
When TRUE the output of the ramp is held at its last value.
RAMPING
PREF: 100.14
Default: FALSE
Range: FALSE / TRUE
Set TRUE when ramping.
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...