A p p e n d i x D : P r o g r a m m i n g
D-79
AC890PX AC Drive
MOTOR PMAC 1
SETUP::MOTOR CONTROL::MOTOR PMAC 1
Designed for PMAC Control Mode.
The MOTOR PMAC blocks (1 & 2) store all the parameters needed to run a PMAC Motor. These parameter values are entered automatically by the
DSE 890 Configuration Tool when the tool is used to select the motor type.
In order for the drive to control the motor the parameters marked
●
MUST
be set.
Parameter Descriptions
MANUFACTURER
PREF: 134.01
Default: PARVEX
Range:
Enter the motor manufacturer's name.
MODEL
PREF: 134.02
Default: HS620EV
Range:
Enter the motor name.
●
CONSTRUCTION
PREF: 134.03
Default: 0
Range: See below
Select the motor’s construction type.
Enumerated Value
:
Construction
0 : AXIS
Standard motor.
1 : SPINDLE Spindle motor.
2 : TORQUE Direct torque motor.
ATMOSPHERE
PREF: 134.04
Default: 0
Range: See below
Select the motor’s atmospheric details.
Enumerated Value
:
Atmosphere
0 : STANDARD
Standard motor.
1 : EXPLOSIVE
Motor built for explosive atmosphere (Ex).
MAX VOLTAGE
PREF: 134.05
Default: 400.00
Range: 200.00 to 640.00 V
Set the motor’s maximum ac input voltage (in Volts rms).
Summary of Contents for AC890PX Series
Page 8: ......
Page 12: ...1 4 C h a p t e r 1 G e t t i n g S t a r t e d AC890PX AC Drive...
Page 17: ...C h a p t e r 2 P r o d u c t O v e r v i e w 2 5 AC890PX AC Drive 890PX bottom wire entry...
Page 22: ...2 10 C h a p t e r 2 P r o d u c t O v e r v i e w AC890PX AC Drive...
Page 74: ...4 8 C h a p t e r 4 A s s o c i a t e d E q u i p m e n t AC890PX AC Drive...
Page 96: ...5 22 C h a p t e r 5 O p e r a t i n g t h e D r i v e AC890PX AC Drive...
Page 162: ...8 22 C h a p t e r 8 T r i p s F a u l t F i n d i n g AC890PX AC Drive...
Page 170: ...9 8 C h a p t e r 9 R o u t i n e M a i n t e n a n c e R e p a i r AC890PX AC Drive...
Page 286: ...D 84 A p p e n d i x D P r o g r a m m i n g AC890PX AC Drive Functional Description...