Install a Second CPU
->
set /SYS/MB/P0 clear_fault_action=true
Are you sure you want to clear /SYS/MB/P0 9y/n)?
y
Set ???clear_fault_action” to ???true???
Related Information
■
■
“Install a Second CPU” on page 166
Install a Second CPU
1.
Prepare the server for service.
See
“Preparing the Server for Component Replacement” on page 75
.
2.
Remove the air duct.
See
“Remove the Air Duct” on page 127
3.
Remove the CPU filler cover from the empty CPU socket.
4.
Clean the top of the CPU with the provided alcohol wipe.
5.
Place the CPU in the socket with the correct orientation.
166
Sun Netra X4270 Server • September 2015