Replacing PCIe2 Risers
6.
Return the server to operation.
“Returning Server to Operation” on page 211
Related Information
■
“Remove the PCI Mezzanine” on page 102
■
“Replacing PCIe2 Risers” on page 107
■
“Replacing PCIe2 Cards in Slots 4 and 5” on page 115
Replacing PCIe2 Risers
PCIe2 cards in slots 0, 1, and 2 are installed on vertical risers. You must remove the relevant
riser to remove and replace a PCIe2 card. You must remove all three PCIe risers when replacing
the motherboard.
Description
Links
Locate the three PCIe2 risers and understand their
differences.
“PCIe2 Riser Location and Differences” on page 107
Remove a PCIe2 riser from the motherboard assembly.
“Remove a PCIe2 Riser” on page 108
Install a PCIe2 riser to the motherboard assembly.
“Install a PCIe2 Riser” on page 110
Related Information
■
“Replacing the PCI Mezzanine” on page 101
■
“Replacing PCIe2 Cards” on page 112
PCIe2 Riser Location and Differences
The motherboard connector for PCIe2 riser 0 is different than the connector used by PCIe2
risers 1 and 2. Do not attempt to install a PCIe2 riser in a different location on the motherboard.
Replacing Motherboard Assembly Components
107
Summary of Contents for Sun Netra X4270
Page 1: ...Sun Netra X4270 Server Service Manual Part No E23171 03 September 2015 ...
Page 2: ......
Page 10: ...10 Sun Netra X4270 Server September 2015 ...
Page 12: ...12 Sun Netra X4270 Server September 2015 ...
Page 36: ...36 Sun Netra X4270 Server September 2015 ...
Page 72: ...72 Sun Netra X4270 Server September 2015 ...
Page 100: ...100 Sun Netra X4270 Server September 2015 ...
Page 224: ...224 Sun Netra X4270 Server September 2015 ...
Page 230: ...WDT W WDT watchdog timers 230 Sun Netra X4270 Server September 2015 ...