![Oracle Sun Netra X4270 Service Manual Download Page 178](http://html1.mh-extra.com/html/oracle/sun-netra-x4270/sun-netra-x4270_service-manual_1646169178.webp)
Reset the BIOS Password and Clear the CMOS NVRAM
3.
Press and release the CLR CMOS button.
4.
Install the PCI mezzanine.
See
“Install the PCI Mezzanine” on page 104
5.
Return the server to operation.
See
“Returning Server to Operation” on page 211
6.
When powering on the server, watch for a message that indicates that NVRAM
has been cleared.
The BIOS password is reset to the default and the CMOS NVRAM is cleared.
Related Information
■
“Using the BIOS Setup Utility” on page 37
■
“Replacing the Motherboard Assembly” on page 168
178