Install the LED Board
3.
Insert the tab on the LED board into the slot on the chassis.
4.
Swing the LED board right to the chassis and tighten the thumbscrew.
5.
Route the LED board cable back into the cable guides along the chassis wall.
If you disconnected the cable from the PCI mezzanine, reattach the cable now.
6.
Install fan tray 0.
See
“Install Fan Tray 0” on page 190
.
7.
Install the air duct.
See
“Install the Air Duct” on page 130
.
202
Sun Netra X4270 Server • September 2015