Power Down Server Gracefully Using the Power Button
This action causes ACPI-enabled operating systems to perform an orderly shutdown of the
operating system. Servers not running ACPI-enabled operating systems shut down to standby
power mode immediately.
When main power is off, the power OK LED on the front panel will begin flashing, indicating
that the server is in standby power mode. See
“System Status LEDs” on page 19
2.
Disconnect the power and data cables from the server.
See
“Disconnect Cables From the Server” on page 80
Caution -
When you use the Power button to enter standby power mode, power is still directed
to the service processor remote management subsystem and power supply fans. To completely
power off the server, you must disconnect the AC or DC power cords from the back of the
power supplies.
Related Information
■
“System Status LEDs” on page 19
■
“Power Down Server Gracefully” on page 76
■
“Power Down Server For an Emergency” on page 79
■
“Disconnect Cables From the Server” on page 80
■
“Power On the Server” on page 214
78
Sun Netra X4270 Server • September 2015
Summary of Contents for Sun Netra X4270
Page 1: ...Sun Netra X4270 Server Service Manual Part No E23171 03 September 2015 ...
Page 2: ......
Page 10: ...10 Sun Netra X4270 Server September 2015 ...
Page 12: ...12 Sun Netra X4270 Server September 2015 ...
Page 36: ...36 Sun Netra X4270 Server September 2015 ...
Page 72: ...72 Sun Netra X4270 Server September 2015 ...
Page 100: ...100 Sun Netra X4270 Server September 2015 ...
Page 224: ...224 Sun Netra X4270 Server September 2015 ...
Page 230: ...WDT W WDT watchdog timers 230 Sun Netra X4270 Server September 2015 ...