Understanding BIOS Booting and Setup
BIOS POST Error Message
Error Type
Resolution
Note -
Where QPI [
x
] equals 0 for QPI Link 0 or 1 for
QPI Link 1.
Uncorrectable Error Detected on Last Boot:IOH(0) PCI-E
[
x
] Error (Please Check SP Log for more Details)
IOH error
■ Press F1 to continue.
■ Check the fault management function and the SP
event log in ILOM for more details.
Note -
Where PCI-E [
x
] port number can range from 1
to 10 depending on the PCI root port on IOH.
Uncorrectable Error Detected on Last Boot:IOH(0) ESI
Error (Please Check SP Log for more Details)
IOH error
■ Press F1 to continue.
■ Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) Thermal
Error (Please Check SP Log for more Details)
IOH error
■ Press F1 to continue.
■ Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) DMA
Error (Please Check SP Log for more Details)
IOH error
■ Press F1 to continue.
■ Check the SP event log for more details.
Uncorrectable Error Detected on Last Boot:IOH(0)
Miscellaneous Error (Please Check SP Log for more
Details)
IOH error
■ Press F1 to continue.
■ Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) VT-d
Error (Please Check SP Log for more Details)
IOH error
■ Press F1 to continue.
■ Check the SP event log in ILOM for more details.
BMC Not Responding
ILOM error
■ Press F1 to continue.
Note -
This error message might display if during the
SP/BIOS communication an internal error occurs. This
error might require you to restart the SP.
■ Primary Slave Hard Disk Error
■ Primary Master Hard Disk Error
■ Secondary Master Hard Disk Error
■ Secondary Slave Hard Disk Error
IDE/ATAPI
error
■ Press F1 to continue.
■ Check the SP event log in ILOM for more details.
Note -
These type of error messages display when the
BIOS is attempting to configure IDE/ATAPI devices in
POST.
Timer Error
8254 timer error
■ Press F1 to continue.
■ Check the SP event log in ILOM for more details.
Note -
This type of error typically indicates an error
while programming the count register of channel 2 of the
8254 timer. This could indicate a problem with system
hardware.
RAM R/W test failed
Memory test
failure
■ Press F1 to continue.
■ Check the SP event log in ILOM for more details.
Note -
This type of error typically indicates that the
RAM read/write test failed.
KBC BAT Test failed
Keyboard
controller basic
■ Press F1 to continue.
■ Check the SP event log in ILOM for more details.
40
Sun Netra X4270 Server • September 2015
Summary of Contents for Sun Netra X4270
Page 1: ...Sun Netra X4270 Server Service Manual Part No E23171 03 September 2015 ...
Page 2: ......
Page 10: ...10 Sun Netra X4270 Server September 2015 ...
Page 12: ...12 Sun Netra X4270 Server September 2015 ...
Page 36: ...36 Sun Netra X4270 Server September 2015 ...
Page 72: ...72 Sun Netra X4270 Server September 2015 ...
Page 100: ...100 Sun Netra X4270 Server September 2015 ...
Page 224: ...224 Sun Netra X4270 Server September 2015 ...
Page 230: ...WDT W WDT watchdog timers 230 Sun Netra X4270 Server September 2015 ...