Serial Management Port
Pin
Signal Description
Pin
Signal Description
1
Request to Send
5
Ground
2
Data Terminal Ready
6
Receive Data
3
Transmit Data
7
Data Set Ready
4
Ground
8
Clear to Send
If you need to connect to the SERIAL MGT port using a cable with either a DB-9 or a DB-
25 connector, follow the pin descriptions in the following tables to create a crossover adapter
appropriate for your serial connection.
TABLE 10
RJ-45 to DB-9 Adapter Crossovers Wiring Reference
Serial Port (RJ-45 Connector)
DB-9 Adapter
Pin
Signal Description
Pin
Signal Description
1
RTS
8
CTS
2
DTR
6
DSR
3
TXD
2
RXD
4
Signal Ground
5
Signal Ground
5
Signal Ground
5
Signal Ground
6
RXD
3
TXD
7
DSR
4
DTR
8
CTS
7
RTS
TABLE 11
RJ-45 to DB-25 Adapter Crossovers Wiring Reference
Serial Port (RJ-45 Connector)
DB-25 Adapter
Pin
Signal Description
Pin
Signal Description
1
RTS
5
CTS
2
DTR
6
DSR
3
TXD
3
RXD
218
Sun Netra X4270 Server • September 2015
Summary of Contents for Sun Netra X4270
Page 1: ...Sun Netra X4270 Server Service Manual Part No E23171 03 September 2015 ...
Page 2: ......
Page 10: ...10 Sun Netra X4270 Server September 2015 ...
Page 12: ...12 Sun Netra X4270 Server September 2015 ...
Page 36: ...36 Sun Netra X4270 Server September 2015 ...
Page 72: ...72 Sun Netra X4270 Server September 2015 ...
Page 100: ...100 Sun Netra X4270 Server September 2015 ...
Page 224: ...224 Sun Netra X4270 Server September 2015 ...
Page 230: ...WDT W WDT watchdog timers 230 Sun Netra X4270 Server September 2015 ...