CHAPTER 8 8-BIT TIMER/EVENT COUNTER 5
User’s Manual U16896EJ2V0UD
312
8.4.8 Cautions
(1) Error on starting timer
An error of up to 1 clock occurs before the match signal is generated after the timer has been started. This is
because the TM5n register is started asynchronously to the count pulse.
Figure 8-8. Count Start Timing of TM5n Register
00H
Timer start
01H
02H
03H
04H
Count pulse
TM5n count value
Remark
n = 0, 1