792
Caller ID information. If the Caller ID information is restricted, the telephone display shows
PRIVATE. If the system cannot provide Caller ID information because the Telco information is not
available, the display shows OUT OF AREA.
Conditions
Primary Rate Interface (PRI):
The system is compatible with ISDN Primary Rate Interface (PRI) services. PRI services
currently supported include:
Basic PRI Call Control (BCC)
Display of incoming
caller’s name and number when allowed by Telco
Routing in the system based on the number the caller dialed
ISDN maintenance functions (such as In Service/Out of Service Messaging)
Speech and 3.1 KHz audio
PRI ability requires the installation of GCD-PRTA. Each PRI circuit provides 24 PRI
channels (23B + D) 4 with 64K Clear Channel response. The T1/PRI Interface uses a single
slot. When installed, the T1/PRI Interface uses the first block of 24 consecutive trunks. For
example, if you have an GCD-4COTA
+
GPZ-4COTE installed for trunks 1~8, the T1/PRI
Interface automatically uses trunks 9~32. If you have GCD-4COTA
+
GPZ-4COTE installed
for trunks 1~8 and 17~24, the T1/PRI uses trunks 25~48. The T1/PRI Interface cannot use
trunks 9~16 (even if available) since they are not part of a consecutive block of 24 trunks.
When using Mobile Extension in a NetLink Network, the ISDN/PRI must be utilized in the
Primary System.
If fractional PRI has the number of ports changed, the Trunk Port number might change
if they become split or fit into an empty gap of trunk ports. For example, if you have a
GCD-4COTA
+
GPZ-4COTE for Trunks ports 1~8 and 17~24 and the PRI (12 ports)
was assigned as 25~36 and the PRI is changed to be eight ports instead of 12 ports,
the new
trunk port numbers would be 9~16 because the eight ports can now fix into the gap without
being split ports. Another example, if you have a GCD-4COTA
+
GPZ-4COTE for Trunks
ports 1~8 and 17~24 and the PRI (8 ports) was assigned as 9~16 and then you change the
PRI to be 12 ports instead of eight, the new trunk ports would be 25~36 because the ports
have to be split to keep the original port numbers, and this is not supported.
If using a CSU/DSU, Program 10-03-13 must be set to 0. If not using a
CSU/DSU, Program 10-03-13 must be set to 1~7 or anything other than 0.
Restrictions for Calling Party Name:
The UNIVERGE SV9100 supports receiving the name from the Network in supported
formats only. Refer to Restrictions for Calling Party Names.
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...