764
Program
Number
Program Name/Description
Input Data
Default
10-28-01
SIP System Information Setup
– Domain
Name
Define the Domain name. This information is
generally provided by the SIP carrier.
Maximum of 64digits.
(Profile 1 ~ Profile 2)
No Setting
10-28-02
SIP System Information Setup
– Host Name
Define the Domain name. This information is
generally provided by the SIP carrier.
Maximum of 48 digits.
(Profile 1 ~ Profile 2)
No Setting
10-28-03
SIP System Information Setup
– Transport
Protocol
Define the Transport type. This option is always
set to UDP.
0 = UDP
1 = TCP
(Profile 1 ~ Profile 2)
0
10-28-05
SIP System Information Setup
– Domain
Assignment
Define the Domain Assignment. This entry is
determined by what information the SIP carrier
provides. If the SIP carrier provides a server
name: [email protected], then
the domain is: L0.cbeyond.net and the host
name is SIPconnect-sca.
0 = IP Address
1 = Domain Name
(Profile 1 ~ Profile 2)
0
10-28-06
SIP System Information Setup
– IP Trunk
Port Binding
Enable/Disable IP Trunk Port binding.
0 = Disable
1 = Enable
(Profile 1 ~ Profile 2)
0
10-29-01
SIP Server Information Setup
– Default
Proxy (Outbound)
Define the SIP Proxy setup, Default Proxy
(Outbound). When SIP trunking is used, this
must be on.
If entries are made in Program 10-29-xx for an
SIP Server and the SIP Server is removed or not
used, the entries in Program 10-29-xx must be set
back to their default settings. Even if Program
10-29-01 is set to 0 (off), the UNIVERGE SV9100
still checks the settings in the remaining 10-29
programs.
0 = Off
1 = On
(Profile 1 ~ Profile 2)
0
10-29-02
SIP Server Information Setup
– Default
Proxy (Inbound)
Define the Default Proxy (Inbound).
0 = Off
1 = On
(Profile 1 ~ Profile 2)
0
10-29-03
SIP Server Information Setup
– Default
Proxy IP Address
Enter the default Proxy IP Address if the SIP
carrier is using an IP address for the proxy. In
most cases, this is left at the default entry as
the domain name is used.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
(Profile 1 ~ Profile 2)
0.0.0.0
10-29-04
SIP Server Information Setup
– Default
Proxy Port Number
Define the Proxy Port Number.
0 ~ 65535
(Profile 1 ~ Profile 2)
5060
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...