855
Program
Number
Program Name/Description
Input Data
Default
15-07-01
Programmable Function Keys
Assign function keys for External Zone Paging
(code 19 + zone), External All Call Paging
(code 20), Internal Zone Paging (code 21 +
zone) or Meet Me Conference/Paging Pickup
(code 23).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-10-06
Class of Service Options (Answer Service)
–
Meet-Me Conference and Paging
Turn Off or On an extension user ability to use
Meet-Me Conference and Paging.
0 = Off
1 = On
COS 1 ~15 = 1
31-02-01
Internal Paging Group Assignment
–
Internal Paging Group Number
Assign extensions to Internal Paging Groups
(i.e., Page Zones).
0 ~ 64
(0 = No Setting)
0 for IP Station
1 for TDM
Station
31-02-02
Internal Paging Group Assignment
–
Internal All Call Paging Receiving
Allow/Prevent All Call Internal Paging for each
extension. If allowed, extension can place and
receive All Call Internal Paging
announcements. If prevented, extensions can
make (not receive) only All Call Internal Paging
announcements. If combined, Paging zones
should be restricted as well, change the internal
page zone group in Program 31-07-01 to 0.
0 = Prevent
1 = Allow
0
31-03-01
Internal Paging Group Settings
– Internal
Paging Group Name
Assign name to Internal Paging Groups (i.e.,
Page Zones). The system shows the name you
program on the telephone display.
Maximum of 12 characters.
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...