1058
-OR-
2.
Press function key (
*
33), the function keys turn red. The key lights after the timer in Program
20-55-01 expires. The sensor is valid.
-OR-
3.
Security Sensor time pattern 1 starts.
Stop Security Operation:
1.
Press
Speaker
and dial
819
+
0
.
-OR-
2.
Press the red lit function key (
*
33), the function keys turn off.
3.
Security Sensor time pattern 1 stops.
When Detect Security Sensor is On:
1.
A Warning message sent to internal page group 1 and external page group 1.
2.
An outgoing call is automatically sent according to setting in speed dial bin 1999.
3.
When destination answers, VRS sends a second message.
4.
Once received, extension 200 can be used for monitoring. To have a two-way conversation, dial
*
.
To Send Warning message:
To send a Warning message, but not as an Emergency call:
Change Program 20-46-05 to
no setting
.
To Place an Emergency Call:
To send an Emergency call, but not as an Warning message:
Set Programs 20-46-02 and 20-46-03 to
0
.
Remote Inspection
<Program>
Program 11-10-49: (619) Auto Dial Setting for Remote
Program 20-45-01: (200) Remote Inspection terminal, 200
Program 20-45-02: (12:00) Ringing start time, 12
o’clock noon
Program 20-45-03: (3) ringing continue time, 3 minutes
Program 20-45-04: (1999) Speed dial bin number, 1999
Program 20-45-05: (1) VRS message number when inspected extension answered, 1
Program 20-45-06: (2) VRS message number when emergency call destination answered, 2 Program 20-
45-07: (3) Times of auto repeat dial, 3
Program 20-45-08: (30) Auto dial calling time, 30 sec
Program 20-45-09: (30) Interval of Auto Dial, 30 sec
Set Up Remote Inspection:
1.
Press
Speaker
and dial
819
.
2.
Dial the Remote Inspection terminal number (1-6).
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...