1396
Program
Number
Program Name/Description
Input Data
Default
20-13-54
Class of Service Options (Supplementary
Service)
– Call Waiting for Standard SIP
Terminal
Set up Call waiting (Off-hook Signaling) for
Standard SIP terminal. When setting this
Program to enable, Program 20-13-05,
20-13-06 and Program 20-09-01, 20-09-07 also
need to be set to Enable.
0 = Disable
1 = Enable
0
20-17-01
Operator Extension
– Operator’s Extension
Number
Define the extension numbers which are to be
used by operators.
Maximum of eight digits.
ext. 101
Caller ID Display After a Call Transfer:
Program
Number
Program Name/Description
Input Data
Default
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-11-06
Class of Service Options (Hold/Transfer
Service)
– Unscreened Transfer (Ring
Inward Transfer)
Turn Off or On an extension user ability to use
Unscreened Transfer.
0 = Off
1 = On
COS 1 ~ 15 = 1
24-02-15
System Options for Transfer
– SIP Out of
Range Timer
When not receiving any response within this
timer setting, system determines SIP terminal is
out of range. When set to 0, timer is invalid.
0 ~ 30 seconds
4
24-09-01
Call Forward Split Settings
– Call
Forwarding Type
Type of Call Forwarding
0 = Call Forwarding Off
1 = Call Forwarding with both
ring
2 = Call Forwarding when no
answer
3 = Call Forwarding all calls
4 = Call Forwarding busy or no
answer
5 = Call Forwarding when busy
0
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...