Program
Number
Program Name/Description
Input Data
Default
20-46-11
Security Sensor Setup
– Interval of Auto
Dial
Assign interval between Auto Dial when making
emergency call.
Security Sensor No.
1 ~ 8
0 = No Call
1 ~ 3600 seconds
0
20-46-12
Security Sensor Setup
– General Purpose
Relay Contact Detector Circuit Setup
Define general purpose relay contact detector
circuit number (programmed in Program 10-41)
for connect security sensor.
Security Sensor No.
1 ~ 8
0 = Not Used
1 ~ 8 = Detect Circuit Number
0
20-47-01
Time Pattern Setting for Watch Mode
–
Watch Mode
Define watch mode on/off against time pattern
1 ~ 8.
Time Pattern 1 ~ 8:
0 =Off
1 = On
0
20-48-01
Time Pattern for Security Sensor
– Security
Sensor
Define security sensor on/off against time
pattern 1 ~ 8.
Time Pattern 1 ~ 8:
0 =Off
1 = On
0
20-55-01
Delay Timer for Security Sensor
– Sensor
Delay Timer
Assign the delay time, when the contact
detection start to work after set the security
sensor. The sensor starts at once in case of set
0.
0 ~ 3600 seconds
60
35-02-22
SMDR Output Options
– Security Auto
Dialing
Select whether the system should display the
SAD (Security Auto Dialing) on SMDR report.
SMDR Port 1 ~ 8:
0 = No Output
1 = Output
0
35-02-23
SMDR Output Options
– Watch Auto Dialing
Select whether the system should display the
WAD (Warning Auto Dialing) on SMDR report.
SMDR Port 1 ~ 8:
0 = No Output
1 = Output
0
90-10-01
System Alarm Setup
– Alarm Type
Set the alarm type 31, 32, 33. Alarm 31
– Auto
dialing after sensor detection.
Alarm 32
– Auto Dialing for Remote Watch
function.
Alarm 33
– Fail to auto dialing of security
function.
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0
90-10-02
System Alarm Setup
– Report
Assign whether or not the alarm information is
reported to the predefined destination in
Program 90-11.
0 = No Report (no autodial)
1 = Report (autodial)
0
90-20-11
Traffic Report Data Setup
– Security Sensor
Dial Record
Assign whether or not the security sensor dial
report is recorded for Record Security sensor
dialing and Remote Inspection dialing.
0 = Not Record
1 = Record
0
Operation
Warning Message (Watch Mode)
< Program >
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...